QUESTION: How to properly mount an Ecowitt Temp & Humidity Sensor inside the MeteoShield Pro?

ANSWER: Due to its short length, the Ecowitt Temp & Humidity Sensor requires the M25 sensor clamp which comes with the MeteoShield Pro mount to be situated on the top of the mount with an additional 5 mm thick spacer to position the sensor at the proper height in the MeteoShield Pro.

The following photos will server as a guide.


Ecowitt Temperature & Humidity Sensor

For the Ecowitt Temperature & Humidity Sensor, the sensor clamp, 5mm spacer, and rubber ring need to be inserted from the top of the MeteoShielD Mount with the tightening nut on the opposite bottom side.

Ecowitt Temperature & Humidity Sensor mounted inside the MeteoShield Pro, due to its short length, requires the sensor clamp to be mounted on top of the MeteoShield mount along with a 5 mm spacer to position the sensor higher in the solar radiation shield.